Sign In | Join Free | My frbiz.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Electric Meter Calibration >

100a Clamp Ct 640×480 LCD Electric Meter Calibration

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

100a Clamp Ct 640×480 LCD Electric Meter Calibration

  • 1
  • 2

Brand Name : GFUVE

Model Number : GF312D1, 0.02%

Certification : CE, CNAS, KEMA

Place of Origin : China

MOQ : 1SET

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 100set/month

Packaging Details : Standard Export Wooden box

Accuracy class : 0.02%, 0.05%

LCD : 6”TFT (640×480) TFT

Power supply : 220V±10%, 50/60Hz, battery, Phase voltage supply

Test voltage Range : 0-600V

Test current  : 0-12A directly, 0-120a clamp on ct

Power measure error  : ±0.02% (0.1A-12A)

Names : 3 Phase Reference Energy Meter Equipment

Weight : 1.6KG

Display digital : 6 bit

Application : Testing three phase energy meter error

Contact Now

100A clamp ct Handheld 3 Phase Reference Energy Meter Equipment for electric meter calibration

Three Phase Multi-function Energy Reference Meters offered by us are used for fundamental function of measuring for voltage, phase, current, frequency, reactive power, active power, power factor and error. Further, these also find application in measuring degree of stability of current, voltage and power.its functions and features︰ The model GF312D1 three phase reference standard is one of the most versatile reference instruments ever. The model GF312D1 has a typical accuracy of ±0.02% @ PF=1 for all measurement functions across its entire operating range, with a maximum worst case accuracy of ±0.04%/PF=0.5C or 0.5L. it can be used many by electrical energy engineer on site. The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters

FEATURES AND FUNCTIONS

  • Display vector diagram.
  • Display waveform of U and I.
  • Analyze and display content of harmonic of U and I.
  • Measure 2-64 harmonic of U, I.
  • Store and display measured data.
  • Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
  • Measure CT variable ratio.
  • Measure the ratio or lag-angle of low-voltage transformer.
  • Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
  • Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
  • Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
  • Three phase active or reactive electricity energy meter.
  • Calibrate three phase, single phase, and active or reactive meter error.
  • Measure U(voltage) of three phase or single phase.
  • Measure I(current) of three phase or single phase.
  • Measure active power of three phase or single phase.
  • Measure reactive power of three phase or single phase.
  • Measure apparent power of three phase or single phase.
  • Measure power factor of three phase or single phase.
  • Measure phase angle between voltage and current.
  • Measure frequency of power line.

PARAMETERS

Electrical parameters 
Accuracy class 0.05%, 0.1%
Resolution 6”TFT (640×480)
Power supply 220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port RS232
Test voltage 
Range 0-480V
Error ±0.05% (30V-480V)
±0.1% (5V-30V)
Harmonic 2nd-64st
Test current 
Range (direct connection) 5mA-20A
Error (direct connection) ±0.05% (100mA-20A)
±0.1% (10mA-100mA)
Range (clamp CT) 10mA-3000A
Error (camp CT) ±0.2% (100mA-100A)
±0.5% (100A-3000A)
Harmonic 2nd-64st
Power measure error 
Active power (direct connection) ±0.02% (0.1A-12A)
±0.05% (0.01A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-12A)
Energy measure error 
Active energy (direct connection) ±0.02% (0.1A-12A)
±0.05% (0.01A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-20A)
Phase angle 
Range 0°-360°
Resolution 0.01°
Error ±0.02°
Frequency 
Range 40-70Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse input 
Input channel 2
Input level 5-24V
Input frequency Max. 2MHz
Pulse output 
Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio 1:1
Output level 5V
Function 
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication with PC Yes
Mechanical parameters 
Instrument dimensions (W×H×D) (mm) 245×162×60
Instrument Weight (kg) 1.6
Carry case dimensions (W×H×D) (mm) 450×320×185
Carry case (kg) 10
Environmental conditions 
Ambient temperature -10°C to 55°C
Relative humidity 15%-85%

PHOTO

100a Clamp Ct 640×480 LCD Electric Meter Calibration


Product Tags:

100a clamp ct

      

100a electric meter calibration

      

640×480 lcd electric meter calibration

      
China 100a Clamp Ct 640×480 LCD Electric Meter Calibration wholesale

100a Clamp Ct 640×480 LCD Electric Meter Calibration Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)